Applications

ECO PHYSICS offers a broad range of NOx analyzers for indoor, ambient, troposheric and stratospheric monitoring.

The principle of chemiluminescence detection is an extremely selective method for measuring nitrogen oxides precisely, with high linearity over a wide concentration range and with very high reproducibility. These qualities are the basis for the acknowledged high performance of ECO PHYSICS CLD NOx analyzers in tracing nitrogen oxides even down to the low ppt level.

Within each series, the second digit in the model name defines the measurement range of your first channel. If you estimate your highest concentration to be below 5000 ppm, you will have the choice of full range of any figure between 5 and 5000 ppm, e.g. 33 ppm or 850 ppm. Please consider, instruments configured with smaller measurement ranges of course possess a higher resolution.

Environmental, Ambient Air and Research

Focuses on low NOX and NOX-related concentrations up to 100 ppm where high resolution is required. Parameters included are NO, NO2, NOX, NH3, NOX-Amines and NOY. Target applications are ambient air monitoring, indoor measurement, clean room measurement and atmospheric research.

nCLD AL2

Ambient Level (QAL1)

Parameters: NO/NO2/NOx

Range: 0-50 ppm

MDL: 0.4 ppb

 

nCLD AL3

Ambient Level

Parameters: NO/NO2/NH3 simultaneous

Range: 0-50 ppm

MDL: 0.4 ppb

 

 

nCLD 88 Yp

Modular Analyzer

Parameters: NO/NOx

Range: 0-5'000 ppb

MDL: 0.05 ppb

Options: sample treatment, calibration valves

nCLD 855 Y

Modular Analyzer

Parameters: NO/NO2/NOx

Range: 0-50 ppm

MDL: 0.4 ppb

Options: sample treatment, calibration valves

 

nCLD 66 Y

Boxed-set

Parameters: NO/NO2/NOx

Range : 0-25 ppm

MDL: 0.25 ppb

nCLD 899 Y

SupremeLine

Parameters: NO/NO2/NOx

Integrated heated inlet, pressure regulation and calibration valves

Range: 0-1 ppm

MDL: 25 ppt

CraNOx II

SupremeLine

Parameters: NO/NO2/NOx/O3

Integrated auto calibration system, zero air generator, photolytic converter for direct NO2 measurement, Ozone correction

Range: 0-1'000 ppb

MDL: 25 ppt

CLD 780 TR

Tropospheric Research Gas Analyzer

Parameters: NO, NOx

Range: 500 ppb

MDL: 3 ppt / 180 s, 10 ppt / 60 s

Options: External converters for NO2/NOy

PAG 003

Pure Air Generator

Auxiliaries

CON 765

NOy - converter

Auxiliaries

Industrial

Focuses on medium NOx, NOx-related and multigas-concentrations up to 5’000 ppm where flexibility is a central requirement. Parameters included are NO, NO2, NOx, NH3, NOx-amines, O2 and CO2. Typical supported applications are industrial emission monitoring and gas manufacturing control.

nCLD 82 S

Modular Analyzer

Parameters: NO/NOx

Range: 0-5'000 ppm

MDL: 0.12 ppm

Options: sample treatment, calibration valves

nCLD 822 CMhr

Modular Analyzer

Parameters: NOx/NH3

Range: 0-5'000 ppm

MDL: 0.12 ppm

Options: sample treatment, calibration valves, switch to NO/NO2

nCLD 84 M

Modular Analyzer

Parameters: NO/NOx

Range: 0-500 ppm

MDL: 0.012 ppm

Options: sample treatment, calibration valves

nCLD 844 M

Modular Analyzer

Parameters: NO/NO2/NOx

Range: 0-500 ppm

MDL: 0.012 ppm

Options: sample treatment, calibration valves

nCLD 822 M

Modular Analyzer

Parameters: NO/NO2/NOx

Range: 0-5'000 ppm

MDL: 0.12 ppm

Options: sample treatment, calibration valves

nCLD 8555 CY

Modular Analyzer

Parameters: NO/NO2/NH3

Range: 0-50 ppm

MDL: 0.4 ppb

for details, go to nCLD AL3

nCLD EL2

Boxed-set (QAL1)

Parameters: NO/NO2/NOx

Integrated heated inlet

Range: 0-5'000 ppm

MDL: 0.125 ppm

nCLD 855 Y

Modular Analyzer

Parameters: NO/NO2/NOx

Range: 0-50 ppm

MDL: 0.4 ppb

Options: sample treatment, calibration valves

nCLD EL

Boxed-set

Parameters: NO / NOx

Range: 0-500 ppm

MDL: 0.05 ppm

Option: NO2 valve

nCLD EL S

Boxed-set

Parameters: NO/NOx

Range: 0-5'000 ppm

MDL: 0.5 ppm

Option: NO2 valve

nCLD EL Max

Multigas under development

PAG 003

Pure Air Generator

Auxiliaries

Automotive, Aviation, Marine, and Combustive Engines

Focuses on high NOx, NOx-related and multigas-concentrations up to 10’000 ppm. Parameters included are NO, NO2, NOx, NH3, NOx-amines, O2 and CO2. The applications are characterized by demanding sample gas conditions, such as in automotive, aviation, naval, or combustive engine emissions, as well as in catalyst production.

nCLD 811 M

SupremeLine

Parameters: NO/NO2/NOx

Integrated heated inlet, pressure regulation and calibration valves

Range: 0-10'000 ppm

MDL: 1 ppb

nCLD 811 CM

SupremeLine

Parameters: NOx/NH3

Integrated heated inlet, pressure regulation and calibration valves

Range: 0-10'000 ppm

MDL: 1 ppb

Option: switch to NO/NO2

nCLD EL

Boxed-set

Parameters: NO / NOx

Range: 0-500 ppm

MDL: 0.05 ppm

Option: NO2 valve

nCLD EL S

Boxed-set

Parameters: NO/NOx

Range: 0-5'000 ppm

MDL: 0.5 ppm

Option: NO2 valve

nCLD EL Max

Multigas under development

PAG 003

Pure Air Generator

Auxiliaries

NO in Liquids

Liquid NO nCLD 88

Nitric Oxide in liquid samples

Parameters: NO/NOx

Range: 0-5'000 ppb

MDL: 0.012ppb

Accessories: Chemostate glassware, noble gas supply, EDAQ-Software system

Semiconductor

NOx detection is an innovative approach in CMP (Chemical Mechanical Polishing) process control. CMP smoothens the wafer surface with a combined chemical and mechanical polishing procedure. During production, wafers are coated by a thin layer. To avoid damage to the wafer surface, for instance by stress cracks, the NOx emitted as soon as the wafer is plane and blank must be measured. Therefore, a high-resolution NOx-detector, capable of determining exactly when the polishing process must be stopped, is essential. This approach is used successfully in manufacturing and development lines worldwide, since 1996.

M 17

End-Point Control System for CMP Process

Medical

Exhaled Nitric Oxide (FeNO) measurements are easy to perform and may be used to monitor eosinophilic airway inflammation (Asthma). A range of computerized pulmonary diagnostic products ranging from neonatology to adult pulmonary function testing are manufactured by ECO PHYSICS AG. These products are marketed and distributed by the label ECO MEDICS.

Visit www.ecomedics.com to learn more about our medical product range.

INTERESTED IN OUR PRODUCTS?

 

If you need help deciding which product suits best your needs,
don’t hesitate to contact us

 

ECO PHYSICS Global Sales, Support and Service Network:

ECO PHYSICS has a strong global network with local sales, support and service representatives. Please select your region and get in contact with us.

Sophisticated solutions for our customers

Our marketing oriented core competence covers customer support, manufacturing and R&D.
We are relying on the best suited partners, internally as well as externally by applying a process oriented management system