Applications
ECO PHYSICS offers a broad range of NOx analyzers for indoor, ambient, troposheric and stratospheric monitoring.
The principle of chemiluminescence detection is an extremely selective method for measuring nitrogen oxides precisely, with high linearity over a wide concentration range and with very high reproducibility. These qualities are the basis for the acknowledged high performance of ECO PHYSICS CLD NOx analyzers in tracing nitrogen oxides even down to the low ppt level.
Within each series, the second digit in the model name defines the measurement range of your first channel. If you estimate your highest concentration to be below 5000 ppm, you will have the choice of full range of any figure between 5 and 5000 ppm, e.g. 33 ppm or 850 ppm. Please consider, instruments configured with smaller measurement ranges of course possess a higher resolution.
Environmental, Ambient Air and Research
Focuses on low NOX and NOX-related concentrations up to 100 ppm where high resolution is required. Parameters included are NO, NO2, NOX, NH3, NOX-Amines and NOY. Target applications are ambient air monitoring, indoor measurement, clean room measurement and atmospheric research.

nCLD AL2
Ambient Level (QAL1)
Parameters: NO/NO2/NOx
Range: 0-50 ppm
MDL: 0.4 ppb
nCLD AL3
Ambient Level
Parameters: NO/NO2/NH3 simultaneous
Range: 0-50 ppm
MDL: 0.4 ppb

nCLD 88 Yp
Modular Analyzer
Parameters: NO/NOx
Range: 0-5'000 ppb
MDL: 0.05 ppb
Options: sample treatment, calibration valves
nCLD 855 Y
Modular Analyzer
Parameters: NO/NO2/NOx
Range: 0-50 ppm
MDL: 0.4 ppb
Options: sample treatment, calibration valves

nCLD 66 Y
Boxed-set
Parameters: NO/NO2/NOx
Range : 0-25 ppm
MDL: 0.25 ppb

nCLD 899 Y
SupremeLine
Parameters: NO/NO2/NOx
Integrated heated inlet, pressure regulation and calibration valves
Range: 0-1 ppm
MDL: 25 ppt
CraNOx II
SupremeLine
Parameters: NO/NO2/NOx/O3
Integrated auto calibration system, zero air generator, photolytic converter for direct NO2 measurement, Ozone correction
Range: 0-1'000 ppb
MDL: 25 ppt



CLD 780 TR
Tropospheric Research Gas Analyzer
Parameters: NO, NOx
Range: 500 ppb
MDL: 3 ppt / 180 s, 10 ppt / 60 s
Options: External converters for NO2/NOy
PAG 003
Pure Air Generator
Auxiliaries
CON 765
NOy - converter
Auxiliaries
Industrial
Focuses on medium NOx, NOx-related and multigas-concentrations up to 5’000 ppm where flexibility is a central requirement. Parameters included are NO, NO2, NOx, NH3, NOx-amines, O2 and CO2. Typical supported applications are industrial emission monitoring and gas manufacturing control.

nCLD 82 S
Modular Analyzer
Parameters: NO/NOx
Range: 0-5'000 ppm
MDL: 0.12 ppm
Options: sample treatment, calibration valves
nCLD 822 CMhr
Modular Analyzer
Parameters: NOx/NH3
Range: 0-5'000 ppm
MDL: 0.12 ppm
Options: sample treatment, calibration valves, switch to NO/NO2
nCLD 84 M
Modular Analyzer
Parameters: NO/NOx
Range: 0-500 ppm
MDL: 0.012 ppm
Options: sample treatment, calibration valves
nCLD 844 M
Modular Analyzer
Parameters: NO/NO2/NOx
Range: 0-500 ppm
MDL: 0.012 ppm
Options: sample treatment, calibration valves
nCLD 822 M
Modular Analyzer
Parameters: NO/NO2/NOx
Range: 0-5'000 ppm
MDL: 0.12 ppm
Options: sample treatment, calibration valves
nCLD 8555 CY
Modular Analyzer
Parameters: NO/NO2/NH3
Range: 0-50 ppm
MDL: 0.4 ppb
for details, go to nCLD AL3
nCLD EL2
Boxed-set (QAL1)
Parameters: NO/NO2/NOx
Integrated heated inlet
Range: 0-5'000 ppm
MDL: 0.125 ppm
nCLD 855 Y
Modular Analyzer
Parameters: NO/NO2/NOx
Range: 0-50 ppm
MDL: 0.4 ppb
Options: sample treatment, calibration valves

nCLD EL
Boxed-set
Parameters: NO / NOx
Range: 0-500 ppm
MDL: 0.05 ppm
Option: NO2 valve
nCLD EL S
Boxed-set
Parameters: NO/NOx
Range: 0-5'000 ppm
MDL: 0.5 ppm
Option: NO2 valve
nCLD EL Max
Multigas under development

PAG 003
Pure Air Generator
Auxiliaries
Automotive, Aviation, Marine, and Combustive Engines
Focuses on high NOx, NOx-related and multigas-concentrations up to 10’000 ppm. Parameters included are NO, NO2, NOx, NH3, NOx-amines, O2 and CO2. The applications are characterized by demanding sample gas conditions, such as in automotive, aviation, naval, or combustive engine emissions, as well as in catalyst production.

nCLD 811 M
SupremeLine
Parameters: NO/NO2/NOx
Integrated heated inlet, pressure regulation and calibration valves
Range: 0-10'000 ppm
MDL: 1 ppb
nCLD 811 CM
SupremeLine
Parameters: NOx/NH3
Integrated heated inlet, pressure regulation and calibration valves
Range: 0-10'000 ppm
MDL: 1 ppb
Option: switch to NO/NO2

nCLD EL
Boxed-set
Parameters: NO / NOx
Range: 0-500 ppm
MDL: 0.05 ppm
Option: NO2 valve
nCLD EL S
Boxed-set
Parameters: NO/NOx
Range: 0-5'000 ppm
MDL: 0.5 ppm
Option: NO2 valve
nCLD EL Max
Multigas under development

PAG 003
Pure Air Generator
Auxiliaries
NO in Liquids

Liquid NO nCLD 88
Nitric Oxide in liquid samples
Parameters: NO/NOx
Range: 0-5'000 ppb
MDL: 0.012ppb
Accessories: Chemostate glassware, noble gas supply, EDAQ-Software system
Semiconductor
NOx detection is an innovative approach in CMP (Chemical Mechanical Polishing) process control. CMP smoothens the wafer surface with a combined chemical and mechanical polishing procedure. During production, wafers are coated by a thin layer. To avoid damage to the wafer surface, for instance by stress cracks, the NOx emitted as soon as the wafer is plane and blank must be measured. Therefore, a high-resolution NOx-detector, capable of determining exactly when the polishing process must be stopped, is essential. This approach is used successfully in manufacturing and development lines worldwide, since 1996.

M 17
End-Point Control System for CMP Process
Medical
Exhaled Nitric Oxide (FeNO) measurements are easy to perform and may be used to monitor eosinophilic airway inflammation (Asthma). A range of computerized pulmonary diagnostic products ranging from neonatology to adult pulmonary function testing are manufactured by ECO PHYSICS AG. These products are marketed and distributed by the label ECO MEDICS.
Visit www.ecomedics.com to learn more about our medical product range.

INTERESTED IN OUR PRODUCTS?
If you need help deciding which product suits best your needs,
don’t hesitate to contact us
ECO PHYSICS Global Sales, Support and Service Network:
ECO PHYSICS has a strong global network with local sales, support and service representatives. Please select your region and get in contact with us.
Sophisticated solutions for our customers
Our marketing oriented core competence covers customer support, manufacturing and R&D.
We are relying on the best suited partners, internally as well as externally by applying a process oriented management system