Parameters

ECO PHYSICS offers a broad range of NOx analyzers for indoor, ambient, tropospheric and stratospheric monitoring.

The principle of chemiluminescence detection is an extremely selective method for measuring nitrogen oxides precisely, with high linearity over a wide concentration range and with very high reproducibility. These qualities are the basis for the acknowledged high performance of ECO PHYSICS CLD NOx analyzers in tracing nitrogen oxides even down to the low ppt level.

Within each series, the second digit in the model name defines the measurement range of your first channel. If you estimate your highest concentration to be below 5000 ppm, you will have the choice of full range of any figure between 5 and 5000 ppm, e.g. 33 ppm or 850 ppm. Please consider, instruments configured with smaller measurement ranges of course possess a higher resolution.

NO/NOx

The following products can be used for the analysis of NO / NOx

nCLD EL S

Boxed-set

Parameters: NO/NOx

Range: 0-5'000 ppm

MDL: 0.5 ppm

Option: NO2 valve

nCLD 66 Y

Boxed-set

Parameters: NO/NO2/NOx

Range : 0-25 ppm

MDL: 0.25 ppb

nCLD EL

Boxed-set

Parameters: NO / NOx

Range: 0-500 ppm

MDL: 0.05 ppm

Option: NO2 valve

nCLD 82 S

Modular Analyzer

Parameters: NO/NOx

Range: 0-5'000 ppm

MDL: 0.12 ppm

Options: sample treatment, calibration valves

nCLD 88 Yp

Modular Analyzer

Parameters: NO/NOx

Range: 0-5'000 ppb

MDL: 0.05 ppb

Options: sample treatment, calibration valves

nCLD 84 M

Modular Analyzer

Parameters: NO/NOx

Range: 0-500 ppm

MDL: 0.012 ppm

Options: sample treatment, calibration valves

CLD 780 TR

Tropospheric Research Gas Analyzer

Parameters: NO, NOx

Range: 500 ppb

MDL: 3 ppt / 180 s, 10 ppt / 60 s

Options: External converters for NO2/NOy

NO, NO2, NOx

The following products can be used for the analysis of NO, NO2, NOx

nCLD AL2

Ambient Level (QAL1)

Parameters: NO/NO2/NOx

Range: 0-50 ppm

MDL: 0.4 ppb

 

nCLD EL2

Boxed-set (QAL1)

Parameters: NO/NO2/NOx

Integrated heated inlet

Range: 0-5'000 ppm

MDL: 0.125 ppm

nCLD 822 M

Modular Analyzer

Parameters: NO/NO2/NOx

Range: 0-5'000 ppm

MDL: 0.12 ppm

Options: sample treatment, calibration valves

nCLD 855 Y

Modular Analyzer

Parameters: NO/NO2/NOx

Range: 0-50 ppm

MDL: 0.4 ppb

Options: sample treatment, calibration valves

 

nCLD 844 M

Modular Analyzer

Parameters: NO/NO2/NOx

Range: 0-500 ppm

MDL: 0.012 ppm

Options: sample treatment, calibration valves

nCLD 811 M

SupremeLine

Parameters: NO/NO2/NOx

Integrated heated inlet, pressure regulation and calibration valves

Range: 0-10'000 ppm

MDL: 1 ppb

nCLD 899 Y

SupremeLine

Parameters: NO/NO2/NOx

Integrated heated inlet, pressure regulation and calibration valves

Range: 0-1 ppm

MDL: 25 ppt

NO, NO2, NOx, NH3, NOx - amines

The following products can be used for the analysis of NO, NO2, NOx, NH3, NO2 – amines

nCLD 811 CM

SupremeLine

Parameters: NOx/NH3

Integrated heated inlet, pressure regulation and calibration valves

Range: 0-10'000 ppm

MDL: 1 ppb

Option: switch to NO/NO2

nCLD 822 CMhr

Modular Analyzer

Parameters: NOx/NH3

Range: 0-5'000 ppm

MDL: 0.12 ppm

Options: sample treatment, calibration valves, switch to NO/NO2

nCLD 8555 CY

Modular Analyzer

Parameters: NO/NO2/NH3

Range: 0-50 ppm

MDL: 0.4 ppb

for details, go to nCLD AL3

nCLD AL3

Ambient Level

Parameters: NO/NO2/NH3 simultaneous

Range: 0-50 ppm

MDL: 0.4 ppb

 

 

NO, NO2, NOx, O3

The following products can be used for the analysis of NO, NO2, NOx, O3

CraNOx II

SupremeLine

Parameters: NO/NO2/NOx/O3

Integrated auto calibration system, zero air generator, photolytic converter for direct NO2 measurement, Ozone correction

Range: 0-1'000 ppb

MDL: 25 ppt

NO in Liquids

The following products can be used for the analysis of NO, NO2, NOx, O3

Liquid NO nCLD 88

Nitric Oxide in liquid samples

Parameters: NO/NOx

Range: 0-5'000 ppb

MDL: 0.012ppb

Accessories: Chemostate glassware, noble gas supply, EDAQ-Software system

INTERESTED IN OUR PRODUCTS?

 

If you need help deciding which product suits best your needs,
don’t hesitate to contact us

 

ECO PHYSICS Global Sales, Support and Service Network:

ECO PHYSICS has a strong global network with local sales, support and service representatives. Please select your region and get in contact with us.

Sophisticated solutions for our customers

Our marketing oriented core competence covers customer support, manufacturing and R&D.
We are relying on the best suited partners, internally as well as externally by applying a process oriented management system